The CASMED 740 MAX NIBP Patient Vital Signs Monitor is a state-of-the-art medical device designed to provide accurate and non-invasive monitoring of essential patient vital signs, with a primary focus on blood pressure measurement. This monitor employs advanced oscillometric technology, utilizing an inflatable cuff placed around the patient’s arm to automatically and accurately measure blood pressure without the need for invasive procedures.
A standout feature of the CASMED 740 MAX NIBP patient vital signs Monitor is its real-time blood pressure monitoring capability. It instantly displays systolic, diastolic, and mean arterial pressure values, providing healthcare professionals with immediate insights into a patient’s cardiovascular status. This real-time data is crucial for making informed medical decisions, particularly in critical care scenarios where rapid interventions are essential.
The monitor’s utility extends beyond blood pressure measurement, offering comprehensive tracking of other vital signs such as heart rate and pulse rate. These additional measurements provide valuable information about a patient’s overall cardiovascular function and health. By presenting a comprehensive view of vital sign trends, the monitor helps clinicians detect fluctuations and abnormalities that may indicate changes in a patient’s condition.
Designed for user-friendliness and efficiency, the CASMED 740 MAX NIBP patient vital signs monitor features an intuitive interface and clear display, simplifying operation and data interpretation. Its automated measurement and display capabilities reduce the need for manual intervention, allowing healthcare professionals to focus on other critical tasks while ensuring continuous monitoring.
The monitor’s portability and compact design make it suitable for various clinical settings, ranging from hospital wards to emergency rooms and outpatient care units. Additionally, it can be seamlessly integrated into hospital networks and electronic health record systems, facilitating data sharing and collaboration among medical teams. This connectivity enhances communication and supports a cohesive approach to patient care.
In summary, the CASMED 740 MAX NIBP Patient Vital Signs Monitor is a cutting-edge medical device that excels in non-invasive blood pressure monitoring and comprehensive vital sign tracking. With its advanced technology, real-time data presentation, user-friendly design, and seamless connectivity, the monitor contributes to improved patient care, clinical decision-making, and efficient healthcare workflows.
NIBP
Technique: Oscillometric (MAXNIBP® Technology)
Patient Range: Adult – Neonate
Measurement Range
Systolic: 30-255 mmHg
Diastolic: 15-220 mmHg
MAP: 20-235 mmHg
Pulse Rate Range: 30-240 BPM
Accuracy
Blood Pressure: ± 5 mmHg standard deviation no greater than 8 mmHg
Pulse Rate: ± 2% or ±2 BPM, whichever is greater
Oximetry (Options) Masimo SET®
SpO2 Range: 0-100%
SpO2 Accuracy:
70-100%, ± 2 digits (1 S.D.) Adult
70-100%, ± 3 digits (1 S.D.) Neonate Pulse Rate Range: 25-240 BPM Pulse Rate Accuracy: ± 3 BPM
Nonin®
SpO2 Range: 0-100%
SpO2 Accuracy:
70-100%, ± 2 digits (1 S.D.) Adult
70-100%, ± 3 digits (1 S.D.) Neonate
Pulse Rate Range: 18-240 BPM
Pulse Rate Accuracy: ± 3% or ±1 digit, whichever is greater
Nellcor® OxiMax® SpO2 Range: 1-100% SpO2 Accuracy:
70-100%, ± 2 digits (1 S.D.) Adult
70-100%, ± 3 digits (1 S.D.) Neonate Pulse Rate Range: 20-240 BPM Pulse Rate Accuracy: ± 3 digits
Temperature (Optional) Welch Allyn SureTemp® Plus
Temperature Range: 29 °C to 42 °C (84.2 °F to 107.6 °F)
Accuracy: ± 0.1 °C (± 0.2 °F) Meets or exceeds ASTM Standards
Control Panel
Display: LED display of measurement results, instructions, troubleshooting messages, and signal strength bar
Parameters Displayed: Systolic Pressure, Diastolic Pressure, Mean Arterial Pressure (MAP), Pulse Rate,
%SpO2, Temperature (°C or °F)
Patient Alarms
Adjustable high and low alarms for Pulse Rate, SpO2, Systolic Pressure, Diastolic Pressure and Mean Arterial Pressure
Operating Modes
History: Review of previous measurements
NIBP: Manual, STAT or Automatic (at preset intervals)
%SpO2: Continuous Monitoring
Temperature: Predictive or Continuous
Power
Source: External line or internal battery
AC Power: 100-240 VAC, 50-60 Hz, 0.5A;
T1.25A L250V fuse rating
DC Power (EMS Option): 12-30 VDC Battery: NiMH battery pack (removable) Charge Time: 4 hours
Operating Time: Minimum 4 hours of continuous operation
Leakage Current: 100 µA (maximum)
Safety Limits
145 mmHg (Neonate)
If measurement time exceeds 120 seconds (Adults), 90 seconds (Neonate)
If safety timer detects microprocessor failure
Operating Environment
Operating Temperature: 0° C to 50° C (32° F to 122° F)
Storage Temperature: -20° C to 65° C (-4° F to 149° F)
Humidity: 15 – 95%, non-condensing
Altitude: Up to 3048 meters (10,000 feet)
if stored or used outside temperature and humidity ranges.
Physical Dimensions & Weight (Base Unit)
H x W x D: 17.0 cm x 21.5 cm x 7.5 cm (6.75 in x 8.5 in x 3.0 in)
Weight: 1.4 kgs (3 lbs)
Standards
ANSI/AAMI SP-10
EN 60601-1, EN 60601-1-2, EN 865, EN 60601-2-30,
EN 60601-2-49
ETL Listed – UL 60601, CAN/CSA C22.2 No. 601.1
CE Marking according to Directive 93/42/EEC
Optional Accessories
Infrared printer RS-232 interface
Swiveled hard mount (for ambulance applications) Roll stand and basket
Protective carrying case